BTU Meters
Static ultrasonic heat and cold meter with integrated M-Bus interface.

All Variants & Sizes
Both models are available through Al Taqa Technical. Contact us for pricing, sizing guidance, and technical support tailored to your project.

QUNDIS Q heat 5.5 US — Integrated BTU Meter
The QUNDIS Q heat 5.5 US is a static ultrasonic heat and cold meter with an all-metal flow sensor and integrated M-Bus interface. Designed for central heating and cooling circuits in commercial and district energy applications, it combines flow sensing and calculator in one compact unit.
| Meter Type | Static ultrasonic heat and cold meter |
|---|---|
| Model | QUNDIS Q heat 5.5 US M-Bus / Impuls-IN |
| Measuring Accuracy | Class 2 or Class 3 (per nominal diameter) |
| Nominal Flow Rate (Qp) | 0.6 / 1.5 / 2.5 / 3.5 / 6.0 / 10.0 m³/h |
| Nominal Diameter (DN) | DN15 / DN20 / DN25 / DN40 |
| Temperature Range | 5°C – 90°C (flow); 0°C – 105°C (calculator) |
| Temperature Difference | 3 K – 70 K; starts at 0.2 K |
| Temperature Sensor | Pt1000 per EN 60751, Type DS |
| Max. Operating Pressure | 16 bar (PN16) |
| Communication | M-Bus (300 / 2400 baud) + 2 pulse inputs |
| Battery Life | 7 years standard (optional 10 years) |
| Display | 8-digit LCD; kWh / MWh / MJ / GJ selectable |
| Protection Rating | IP65 (EN 60529) |
| Standards | MID 2014/32/EU, RoHS 2011/65/EU, EMC 2014/30/EU |
| Cable Length | 80 cm (calculator to flow sensor) |

QUNDIS Q heat Split — Series 473 Ultrasonic Flow Sensor
The QUNDIS Series 473 is a MID-compliant ultrasonic flow sensor in all-metal brass design, covering nominal flow rates from 0.6 to 100 m³/h. It operates as the flow-sensing component of a split heat meter system, paired with a separate QUNDIS R20/R21 calculator unit. Its high dynamic range (up to 1:250), any-position installation, and wide temperature capability (up to 150 °C) make it ideal for large commercial, district heating, and industrial energy metering installations.
| Model | QUNDIS Series 473 Ultrasonic Volume Measuring Part |
|---|---|
| Approval | MID (DE-07-MI004-PTB022), EN 1434 Class 2 |
| Nominal Flow Rate (Qp) | 0.6 – 100 m³/h |
| Nominal Diameter (DN) | DN15 / DN20 / DN25 / DN32 / DN40 / DN50 / DN65 / DN80 / DN100 |
| Dynamic Range | Up to 1:250 |
| Temperature Range (Heat) | 5°C – 130°C (DN15–DN25); up to 150°C (DN32 and above) |
| Temperature Range (Cold) | 5°C – 50°C |
| Ambient Temperature | 5°C – 55°C |
| Max. Operating Pressure | 16 bar (thread); 25 bar (flange) |
| Flow Sensor Body Material | Brass |
| Power Supply | External 3.0 V – 5.5 V DC (via calculator unit) |
| Output | Open Collector pulse output (high-resolution test pulse or communication) |
| Pulse Cable Length | 2.4 m |
| Installation Position | Any (including overhead) |
| Protection Rating | IP54 |
| Standards | EN 1434, MID 2014/32/EU, AGFW 510, VDI 2035; EN 301 489-1/-3 |
| Compatible Calculator Units | QUNDIS R20 / R21 (walk-by or AMR via radio add-on module) |
- District Cooling
- Commercial Buildings
- Utilities
- Industrial Facilities
Compatible with leading BMS platforms including Johnson Controls, Schneider Electric, Honeywell, and Tridium for a unified view of your facility's energy performance.